* moved pmem setting restore before top bar is loaded
* added a check pmem from sdcard function, replaced occurences, added a save to file on back button
* Added defines for flag file and dump file, changed test func name to should_use_sdcard_for_pmem, used file_exists, removed save and load pmem parameter
* changed a text to a more comprehesible one
* WIP file editing
* WIP file editing
* Add "on_pop" handler to navigation.
* WIP Editing
* WIP for draft
* Fix mock and unit tests, support +newline at end.
* Clean up Painter API and use string_view
* Fix optional rvalue functions
* Fix Result 'take' to be more standard
* FileWrapper stack buffer reads
* Grasping at straws
* Nit
* Move set_on_pop impl to cpp
* Workaround "Open" when file not dirty.
---------
Co-authored-by: kallanreed <kallanreed@outlook.com>
* Support for 3 levels of rotary encoder sensitivity #965
Backend support; UI will still need to call set function to configure.
* Support for 3 levels of rotary encoder sensitivity #965
Backend support only. UI will still need to be changed to call the set_sensitivity() function to configure.
* Removed trailing space
* Deleted blank lines to see if format checker will be happier
* Simpler support for multiple levels of encoder sensitivity, for issue #965
Removed the convoluted code :-) and instead just using a 2-dimensional array to choose which transition map to use. For now I only have 2 (vs 3) levels enabled as well, to save code space and because high-sensitivity is very touchy.
* Simpler version of configurable encoder sensitivity, issue #965
* Formatting
* Formatting test for Clang
* Formatting test
* Formatting (removed helpful comment)
* Formatting test (remove commented-out code)
* Formatting & swapping medium/low so default mode=0
* Swapped medium/low so default mode=0
* Adding UI & PMEM support to make encoder dial sensitivity configurable, issue #965
* Adding UI & PMEM support to make encoder dial sensitivity configurable, issue #965
* Adding UI & PMEM support to make encoder dial sensitivity configurable, issue #965
* Adding UI & PMEM support to make encoder dial sensitivity configurable, issue #965
* Adding UI & PMEM support to make encoder dial sensitivity configurable, issue #965
* Adding UI & PMEM support to make encoder dial sensitivity configurable, issue #965
* Removed unneeded range check (trusting in pmem checksum)
* easier 'now', start adding text editor
* Adding scrolling to notepad
* Better scrolling
* Better scrolling, off-by-1 bugs
* MVP fit and finish
* Add tiny font and use in Notepad
* Font tweaking, tiny font cursor
* Fix warning
* Format changed files
* WIP No file limit
* WIP - adding CircularBuffer type
* WIP Caching
* add unit test for circular_buffer
* WIP still have a bug when moving cache forward
* Finish lazy line caching
---------
Co-authored-by: kallanreed <kallanreed@outlook.com>
* fix units for frequency offset. It was planned to be a uint32_t since a uint16_t is obviously too short
* took the uint32_t limitation for frequency offset in account
* easier 'now', start adding text editor
* Adding scrolling to notepad
* Better scrolling
* Better scrolling, off-by-1 bugs
* MVP fit and finish
* Add tiny font and use in Notepad
* Font tweaking, tiny font cursor
* Fix warning
* Format changed files
---------
Co-authored-by: kallanreed <kallanreed@outlook.com>
-Enhanced frequency file reading:
Correctly read freq files that contain a mix of SINGLE and RANGE or HAM_RADIO types (strstr in file processing was ignoring EOL and was therefore finding the f= on the next line). Also changed to simply ignore blank or unrecognized lines versus adding them as SIMPLE entries to freq table.
This allow comments and white line in freqman files.
-Fixed "can_loop" option in NumberField:
When NumberField range.first was non-zero, and can_loop was true, turning the encoder dial in the downward direction did not result in numbers looping back to range.second as was expected. This fix allows looping in downward direction in the case where range.first is non-zero.
Fixed issue with temperature & pressure values for OOK-8400-Schrader TPMS sensor type 5 (temperature & pressure were swapped and using wrong conversion ratio). Tested fix against 14 sensors of this type.
* Added HamItUp option to allow quick offset of the tuned frequency
* New HamItUp icon for top bar
* HamItUp checkbox status and frequency persistent settings in Settings/Radio