Understanding and fixing issues with time/clock in Qubes OS
Note: the content here is for Qubes 4.0, some things may be different in Qubes 3.2.
Architecture
Timezone
The system's timezone is set in dom0.
VMs can read the system's timezone value from dom0 through the QubesDB qubes-timezone
key. On Linux VMs with qubes-core-agent
installed the time zone is set at boot time by the /usr/lib/qubes/init/qubes-early-vm-config.sh
script.
Clock synchronization
A VM is defined globally as "clockVM", from which other VMs and dom0 will synchronize their clock with. The following command in dom0 shows which VM is defined:
qubes-prefs clockvm
By default the clockvm is sys-net. The clockVM's clock is synchronized with remote NTP servers automatically by the systemd-timesyncd
service.
The clockVM has the clocksync
Qubes service enabled (as shown by qvm-service
or in the Services tab in sys-net Qubes Setting GUI): various scripts and systemd service definitions test for the presence (or absence) of /var/run/qubes-service/clocksync
to differentiate the clockVM from other VMs, which allows the clockVM to be based on the same template than other VMs.
Clock synchonization in other VMs is done:
- at boot time, by the
qubes-sync-time
service - after suspend, by
/etc/qubes/suspend-post.d/qvm-sync-clock.sh
- every 6 hours, by the
qubes-sync-time.timer
systemd timer
Those scripts run /usr/bin/qvm-sync-clock
which uses the qubes.GetDate
RPC call to obtain the date from the clockVM and run /usr/lib/qubes/qubes-sync-clock
to validate the data received and set the date.
Clock synchonization in dom0 is done by the /etc/cron.d/qubes-sync-clock.cron
cron job run every hour, which calls /usr/bin/qvm-sync-clock
(despite scripts having the same filename in dom0 and VMs, they are different, but the end result is the same: qubes.GetDate
RPC call, innput validation, and setting the date).
Debugging problems
Time off by X hours
A common issue is to have the time off by a number of hours. There are usually two causes:
- Wrong configured timezone.
- MS Windows was used before installing Qubes OS (or in the case of dual-boot installations). Windows stores the time in the hardware clock as "local time" while Linux stores the time as UTC.
To check that the timezone is OK in dom0, run timedatectl
. Alternatively, look at the /etc/localtime
symlink: it should point to a timezone in /usr/share/zoneinfo
. If you need to change the timezone in dom0, you can use
sudo timedatectl set-timezone "Australia/Queensland"
or
sudo rm /etc/localtime
sudo ln -s /usr/share/zoneinfo/Australia/Queensland /etc/localtime
To set the system's hardware clock to UTC, run the following command in the clockVM (usually sys-net):
sudo hwclock --systohc --utc
Then the easiest way to have the changes applied to all VMs is to do a full reboot.
Wrong time/date
It is also possible that the clockVM's clock isn't properly synchronized with remote NTP servers. Check the status of the systemd-timesyncd service with systemctl status systemd-timesyncd
in the clockVM (usuall sys-net):
● systemd-timesyncd.service - Network Time Synchronization
Loaded: loaded (/usr/lib/systemd/system/systemd-timesyncd.service; enabled; vendor preset: enabled)
Drop-In: /usr/lib/systemd/system/systemd-timesyncd.service.d
└─30_qubes.conf
Active: active (running) since Sun 2018-04-29 06:59:59 EEST; 1 weeks 1 days ago
Docs: man:systemd-timesyncd.service(8)
Main PID: 16966 (systemd-timesyn)
Status: "Synchronized to time server 95.87.227.232:123 (0.fedora.pool.ntp.org)."
Tasks: 2 (limit: 4915)
CGroup: /system.slice/systemd-timesyncd.service
└─16966 /usr/lib/systemd/systemd-timesyncd
In the output above, the clock was successfully synchronized with the 0.fedora.pool.ntp.org
server. The output might be empty if logs were rotated though, in that case restart the service with systemctl restart systemd-timesyncd
and recheck its status.
No clock synchronization usually means the clockVM has a problem with networking.