mirror of
https://git.anonymousland.org/anonymousland/synapse-product.git
synced 2024-12-24 21:09:23 -05:00
00b24aa545
This modifies the configuration of structured logging to be usable from the standard Python logging configuration. This also separates the formatting of logs from the transport allowing JSON logs to files or standard logs to sockets.
323 lines
11 KiB
Python
323 lines
11 KiB
Python
# -*- coding: utf-8 -*-
|
|
# Copyright 2014-2016 OpenMarket Ltd
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License");
|
|
# you may not use this file except in compliance with the License.
|
|
# You may obtain a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS,
|
|
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
# See the License for the specific language governing permissions and
|
|
# limitations under the License.
|
|
import argparse
|
|
import logging
|
|
import logging.config
|
|
import os
|
|
import sys
|
|
import threading
|
|
from string import Template
|
|
|
|
import yaml
|
|
|
|
from twisted.logger import (
|
|
LogBeginner,
|
|
STDLibLogObserver,
|
|
eventAsText,
|
|
globalLogBeginner,
|
|
)
|
|
|
|
import synapse
|
|
from synapse.app import _base as appbase
|
|
from synapse.logging._structured import setup_structured_logging
|
|
from synapse.logging.context import LoggingContextFilter
|
|
from synapse.logging.filter import MetadataFilter
|
|
from synapse.util.versionstring import get_version_string
|
|
|
|
from ._base import Config, ConfigError
|
|
|
|
DEFAULT_LOG_CONFIG = Template(
|
|
"""\
|
|
# Log configuration for Synapse.
|
|
#
|
|
# This is a YAML file containing a standard Python logging configuration
|
|
# dictionary. See [1] for details on the valid settings.
|
|
#
|
|
# Synapse also supports structured logging for machine readable logs which can
|
|
# be ingested by ELK stacks. See [2] for details.
|
|
#
|
|
# [1]: https://docs.python.org/3.7/library/logging.config.html#configuration-dictionary-schema
|
|
# [2]: https://github.com/matrix-org/synapse/blob/master/docs/structured_logging.md
|
|
|
|
version: 1
|
|
|
|
formatters:
|
|
precise:
|
|
format: '%(asctime)s - %(name)s - %(lineno)d - %(levelname)s - \
|
|
%(request)s - %(message)s'
|
|
|
|
handlers:
|
|
file:
|
|
class: logging.handlers.TimedRotatingFileHandler
|
|
formatter: precise
|
|
filename: ${log_file}
|
|
when: midnight
|
|
backupCount: 3 # Does not include the current log file.
|
|
encoding: utf8
|
|
|
|
# Default to buffering writes to log file for efficiency. This means that
|
|
# will be a delay for INFO/DEBUG logs to get written, but WARNING/ERROR
|
|
# logs will still be flushed immediately.
|
|
buffer:
|
|
class: logging.handlers.MemoryHandler
|
|
target: file
|
|
# The capacity is the number of log lines that are buffered before
|
|
# being written to disk. Increasing this will lead to better
|
|
# performance, at the expensive of it taking longer for log lines to
|
|
# be written to disk.
|
|
capacity: 10
|
|
flushLevel: 30 # Flush for WARNING logs as well
|
|
|
|
# A handler that writes logs to stderr. Unused by default, but can be used
|
|
# instead of "buffer" and "file" in the logger handlers.
|
|
console:
|
|
class: logging.StreamHandler
|
|
formatter: precise
|
|
|
|
loggers:
|
|
synapse.storage.SQL:
|
|
# beware: increasing this to DEBUG will make synapse log sensitive
|
|
# information such as access tokens.
|
|
level: INFO
|
|
|
|
twisted:
|
|
# We send the twisted logging directly to the file handler,
|
|
# to work around https://github.com/matrix-org/synapse/issues/3471
|
|
# when using "buffer" logger. Use "console" to log to stderr instead.
|
|
handlers: [file]
|
|
propagate: false
|
|
|
|
root:
|
|
level: INFO
|
|
|
|
# Write logs to the `buffer` handler, which will buffer them together in memory,
|
|
# then write them to a file.
|
|
#
|
|
# Replace "buffer" with "console" to log to stderr instead. (Note that you'll
|
|
# also need to update the configuration for the `twisted` logger above, in
|
|
# this case.)
|
|
#
|
|
handlers: [buffer]
|
|
|
|
disable_existing_loggers: false
|
|
"""
|
|
)
|
|
|
|
LOG_FILE_ERROR = """\
|
|
Support for the log_file configuration option and --log-file command-line option was
|
|
removed in Synapse 1.3.0. You should instead set up a separate log configuration file.
|
|
"""
|
|
|
|
|
|
class LoggingConfig(Config):
|
|
section = "logging"
|
|
|
|
def read_config(self, config, **kwargs):
|
|
if config.get("log_file"):
|
|
raise ConfigError(LOG_FILE_ERROR)
|
|
self.log_config = self.abspath(config.get("log_config"))
|
|
self.no_redirect_stdio = config.get("no_redirect_stdio", False)
|
|
|
|
def generate_config_section(self, config_dir_path, server_name, **kwargs):
|
|
log_config = os.path.join(config_dir_path, server_name + ".log.config")
|
|
return (
|
|
"""\
|
|
## Logging ##
|
|
|
|
# A yaml python logging config file as described by
|
|
# https://docs.python.org/3.7/library/logging.config.html#configuration-dictionary-schema
|
|
#
|
|
log_config: "%(log_config)s"
|
|
"""
|
|
% locals()
|
|
)
|
|
|
|
def read_arguments(self, args):
|
|
if args.no_redirect_stdio is not None:
|
|
self.no_redirect_stdio = args.no_redirect_stdio
|
|
if args.log_file is not None:
|
|
raise ConfigError(LOG_FILE_ERROR)
|
|
|
|
@staticmethod
|
|
def add_arguments(parser):
|
|
logging_group = parser.add_argument_group("logging")
|
|
logging_group.add_argument(
|
|
"-n",
|
|
"--no-redirect-stdio",
|
|
action="store_true",
|
|
default=None,
|
|
help="Do not redirect stdout/stderr to the log",
|
|
)
|
|
|
|
logging_group.add_argument(
|
|
"-f", "--log-file", dest="log_file", help=argparse.SUPPRESS,
|
|
)
|
|
|
|
def generate_files(self, config, config_dir_path):
|
|
log_config = config.get("log_config")
|
|
if log_config and not os.path.exists(log_config):
|
|
log_file = self.abspath("homeserver.log")
|
|
print(
|
|
"Generating log config file %s which will log to %s"
|
|
% (log_config, log_file)
|
|
)
|
|
with open(log_config, "w") as log_config_file:
|
|
log_config_file.write(DEFAULT_LOG_CONFIG.substitute(log_file=log_file))
|
|
|
|
|
|
def _setup_stdlib_logging(config, log_config_path, logBeginner: LogBeginner) -> None:
|
|
"""
|
|
Set up Python standard library logging.
|
|
"""
|
|
if log_config_path is None:
|
|
log_format = (
|
|
"%(asctime)s - %(name)s - %(lineno)d - %(levelname)s - %(request)s"
|
|
" - %(message)s"
|
|
)
|
|
|
|
logger = logging.getLogger("")
|
|
logger.setLevel(logging.INFO)
|
|
logging.getLogger("synapse.storage.SQL").setLevel(logging.INFO)
|
|
|
|
formatter = logging.Formatter(log_format)
|
|
|
|
handler = logging.StreamHandler()
|
|
handler.setFormatter(formatter)
|
|
logger.addHandler(handler)
|
|
else:
|
|
# Load the logging configuration.
|
|
_load_logging_config(log_config_path)
|
|
|
|
# We add a log record factory that runs all messages through the
|
|
# LoggingContextFilter so that we get the context *at the time we log*
|
|
# rather than when we write to a handler. This can be done in config using
|
|
# filter options, but care must when using e.g. MemoryHandler to buffer
|
|
# writes.
|
|
|
|
log_context_filter = LoggingContextFilter(request="")
|
|
log_metadata_filter = MetadataFilter({"server_name": config.server_name})
|
|
old_factory = logging.getLogRecordFactory()
|
|
|
|
def factory(*args, **kwargs):
|
|
record = old_factory(*args, **kwargs)
|
|
log_context_filter.filter(record)
|
|
log_metadata_filter.filter(record)
|
|
return record
|
|
|
|
logging.setLogRecordFactory(factory)
|
|
|
|
# Route Twisted's native logging through to the standard library logging
|
|
# system.
|
|
observer = STDLibLogObserver()
|
|
|
|
threadlocal = threading.local()
|
|
|
|
def _log(event):
|
|
if "log_text" in event:
|
|
if event["log_text"].startswith("DNSDatagramProtocol starting on "):
|
|
return
|
|
|
|
if event["log_text"].startswith("(UDP Port "):
|
|
return
|
|
|
|
if event["log_text"].startswith("Timing out client"):
|
|
return
|
|
|
|
# this is a workaround to make sure we don't get stack overflows when the
|
|
# logging system raises an error which is written to stderr which is redirected
|
|
# to the logging system, etc.
|
|
if getattr(threadlocal, "active", False):
|
|
# write the text of the event, if any, to the *real* stderr (which may
|
|
# be redirected to /dev/null, but there's not much we can do)
|
|
try:
|
|
event_text = eventAsText(event)
|
|
print("logging during logging: %s" % event_text, file=sys.__stderr__)
|
|
except Exception:
|
|
# gah.
|
|
pass
|
|
return
|
|
|
|
try:
|
|
threadlocal.active = True
|
|
return observer(event)
|
|
finally:
|
|
threadlocal.active = False
|
|
|
|
logBeginner.beginLoggingTo([_log], redirectStandardIO=not config.no_redirect_stdio)
|
|
if not config.no_redirect_stdio:
|
|
print("Redirected stdout/stderr to logs")
|
|
|
|
|
|
def _load_logging_config(log_config_path: str) -> None:
|
|
"""
|
|
Configure logging from a log config path.
|
|
"""
|
|
with open(log_config_path, "rb") as f:
|
|
log_config = yaml.safe_load(f.read())
|
|
|
|
if not log_config:
|
|
logging.warning("Loaded a blank logging config?")
|
|
|
|
# If the old structured logging configuration is being used, convert it to
|
|
# the new style configuration.
|
|
if "structured" in log_config and log_config.get("structured"):
|
|
log_config = setup_structured_logging(log_config)
|
|
|
|
logging.config.dictConfig(log_config)
|
|
|
|
|
|
def _reload_logging_config(log_config_path):
|
|
"""
|
|
Reload the log configuration from the file and apply it.
|
|
"""
|
|
# If no log config path was given, it cannot be reloaded.
|
|
if log_config_path is None:
|
|
return
|
|
|
|
_load_logging_config(log_config_path)
|
|
logging.info("Reloaded log config from %s due to SIGHUP", log_config_path)
|
|
|
|
|
|
def setup_logging(
|
|
hs, config, use_worker_options=False, logBeginner: LogBeginner = globalLogBeginner
|
|
) -> None:
|
|
"""
|
|
Set up the logging subsystem.
|
|
|
|
Args:
|
|
config (LoggingConfig | synapse.config.worker.WorkerConfig):
|
|
configuration data
|
|
|
|
use_worker_options (bool): True to use the 'worker_log_config' option
|
|
instead of 'log_config'.
|
|
|
|
logBeginner: The Twisted logBeginner to use.
|
|
|
|
"""
|
|
log_config_path = (
|
|
config.worker_log_config if use_worker_options else config.log_config
|
|
)
|
|
|
|
# Perform one-time logging configuration.
|
|
_setup_stdlib_logging(config, log_config_path, logBeginner=logBeginner)
|
|
# Add a SIGHUP handler to reload the logging configuration, if one is available.
|
|
appbase.register_sighup(_reload_logging_config, log_config_path)
|
|
|
|
# Log immediately so we can grep backwards.
|
|
logging.warning("***** STARTING SERVER *****")
|
|
logging.warning("Server %s version %s", sys.argv[0], get_version_string(synapse))
|
|
logging.info("Server hostname: %s", config.server_name)
|
|
logging.info("Instance name: %s", hs.get_instance_name())
|