The aim here is to move the command handling out of the TCP protocol classes and to also merge the client and server command handling (so that we can reuse them for redis protocol). This PR simply moves the client paths to the new `ReplicationCommandHandler`, a future PR will move the server paths too.
* Remove `conn_id` usage for UserSyncCommand.
Each tcp replication connection is assigned a "conn_id", which is used
to give an ID to a remotely connected worker. In a redis world, there
will no longer be a one to one mapping between connection and instance,
so instead we need to replace such usages with an ID generated by the
remote instances and included in the replicaiton commands.
This really only effects UserSyncCommand.
* Add CLEAR_USER_SYNCS command that is sent on shutdown.
This should help with the case where a synchrotron gets restarted
gracefully, rather than rely on 5 minute timeout.
This changes the replication protocol so that the server does not send down `RDATA` for rows that happened before the client connected. Instead, the server will send a `POSITION` and clients then query the database (or master out of band) to get up to date.
* Port synapse.replication.tcp to async/await
* Newsfile
* Correctly document type of on_<FOO> functions as async
* Don't be overenthusiastic with the asyncing....
`__str__` depended on `self.addr`, which was absent from
ClientReplicationStreamProtocol, so attempting to call str on such an object
would raise an exception.
We can calculate the peer addr from the transport, so there is no need for addr
anyway.
Run the handlers for replication commands as background processes. This should
improve the visibility in our metrics, and reduce the number of "running db
transaction from sentinel context" warnings.
Ideally it means converting the things that fire off deferreds into the night
into things that actually return a Deferred when they are done. I've made a bit
of a stab at this, but it will probably be leaky.
Otherwise the streams don't advance and steadily fall behind, so when a
worker does connect either a) they'll be streamed lots of old updates or
b) the connection will fail as the streams are too far behind.