Importing should work, simply make sure that you are not using Xen's newer linux stubdomain and that the VM is in HVM mode (these steps should be done automatically when importing the VM):
~~~
qvm-features VMNAME linux-stubdom ''
qvm-prefs VMNAME virt_mode hvm
~~~
Note however that you are better off creating a new Windows VM to benefit from the more recent emulated hardware: R3.2 uses a MiniOS based stubdomain with an old and mostly unmaintained 'qemu-traditional' while R4.0 uses a Linux based stubdomain with a recent version of upstream qemu (see [this post](https://groups.google.com/d/msg/qubes-devel/tBqwJmOAJ94/xmFCGJnuAwAJ)).
- Qubes Windows Tools (QWT) only supports Windows 7 x64. Note that there are [known issues](https://github.com/QubesOS/qubes-issues/issues/3585) with QWT on Qubes 4.x
- For Windows 10 under Qubes 4.0, a way to install QWT 4.0.1.3, which has worked in several instances, is described in [Qubes Windows Tools](./windows-tools.md).
Windows' installer requires a significant amount of memory or else the VM will crash with such errors:
`/var/log/xen/console/hypervisor.log`:
> p2m_pod_demand_populate: Dom120 out of PoD memory! (tot=102411 ents=921600 dom120)
> (XEN) domain_crash called from p2m-pod.c:1218
> (XEN) Domain 120 (vcpu#0) crashed on cpu#3:
So, increase the VM's memory to 4096MB (memory = maxmem because we don't use memory balancing).
~~~
qvm-prefs win7new memory 4096
qvm-prefs win7new maxmem 4096
~~~
Disable direct boot so that the VM will go through the standard cdrom/HDD boot sequence:
~~~
qvm-prefs win7new kernel ''
~~~
A typical Windows 7 installation requires between 15GB up to 19GB of disk space depending on the version (Home/Professional/...). Windows updates also end up using significant space. So, extend the root volume from the default 10GB to 25GB (note: it is straightforward to increase the root volume size after Windows is installed: simply extend the volume again in dom0 and then extend the system partition with Windows's disk manager).
The second part of the installation process will crash with the standard VGA video adapter and the VM will stay in "transient" mode with the following error in `guest-win7new-dm.log`:
The VM is now ready to be started; the best practice is to use an installation ISO [located in a VM](/doc/standalone-and-hvm/#installing-an-os-in-an-hvm):
Given the higher than usual memory requirements of Windows, you may get a `Not enough memory to start domain 'win7new'` error. In that case try to shutdown unneeded VMs to free memory before starting the Windows VM.
The VM will shutdown after the installer completes the extraction of Windows installation files. It's a good idea to clone the VM now (eg. `qvm-clone win7new win7newbkp1`). Then, (re)start the VM with `qvm-start win7new`.
Revert to the standard VGA adapter: the 'cirrus' adapter will limit the maximum screen resolution to 1024x768 pixels, while the default VGA adapter allows for much higher resolutions (up to 2560x1600 pixels).
Finally, increase the VM's `qrexec_timeout`: in case you happen to get a BSOD or a similar crash in the VM, utilities like chkdsk won't complete on restart before qrexec_timeout automatically halts the VM. That can really put the VM in a totally unrecoverable state, whereas with higher qrexec_timeout, chkdsk or the appropriate utility has plenty of time to fix the VM. Note that Qubes Windows Tools also require a larger timeout to move the user profiles to the private volume the first time the VM reboots after the tools' installation.
At that point you should have a functional and stable Windows VM, although without updates, Xen's PV drivers nor Qubes integration (see sections [Windows Update](#windows-update) and [Xen PV drivers and Qubes Windows Tools](./windows-tools.md#xen-pv-drivers-and-qubes-windows-tools)). It is a good time to clone the VM again.
when creating the VM. To have the user data stored in AppVMs depending on this template, Windows 7 and 10 have to be treated differently:
- For Windows 7, the option to move the user directories from drive `C` to drive `D` works and causes any user data to be stored in the AppVMs based on this template, and not in the template itself.
- After installation of Windows 10 as a TemplateVM, the Windows disk manager may be used to add the private volume as disk `D:`, and you may, using the documented Windows operations, move the user directories `C:\users\<username>\Documents` to this new disk, allowing depending AppVMs to have their own private volumes. Moving the hidden application directories `AppData`, however, is likely to invite trouble - the same trouble that occurs if, during QWT installation, the option `Move user profiles` is selected.
For Windows 10, configuration data like those stored in directories like `AppData` still remain in the TemplateVM, such that their changes are lost each time the AppVM shuts down. In order to make permanent changes to these configuration data, they have to be changed in the TemplateVM, meaning that applications have to be started there, which violates and perhaps even endangers the security of the TemplateVM. Such changes should be done only if absolutely necessary and with great care. It is a good idea to test them first in a cloned TemplateVM before applying them in the production VM.
AppVMs based on these templates can be created the normal way by using the Qube Manager or by specifying
~~~
qvm-create --class=AppVM --template=<VMname>
~~~
On starting the AppVM, sometimes a message is displayed that the Xen PV Network Class needs to restart the system. This message can be safely ignored and closed by selecting "No".
**Caution:** These AppVMs must not be started while the corresponding TemplateVM is running, because they share the TemplateVM's license data. Even if this could work sometimes, it would be a violation of the license terms.
If Windows 10 is used in the EU to process personal data, according to GDPR no automatic data transfer to countries outside the EU is allowed without explicit consent of the person(s) concerned, or other legal consent, as applicable. Since no reliable way is found to completely control the sending of telemetry from Windows 10, the system containing personal data must be completely shielded from the internet.
This can be achieved by installing Windows 10 on a TemplateVM with the user data directory moved to a separate drive (usually `D:`). Personal data must not be stored within the TemplateVM, but only in AppVMs depending on this TemplateVM. Network access by these AppVMs must be restricted to the local network and perhaps additional selected servers within the EU. Any data exchange of the AppVMs must be restricted to file and clipboard operations to and from other VMs in the same Qubes system.
Depending on how old your installation media is, fully updating your Windows VM may take *hours* (this isn't specific to Xen/Qubes) so make sure you clone your VM between the mandatory reboots in case something goes wrong. This [comment](https://github.com/QubesOS/qubes-issues/issues/3585#issuecomment-366471111) provides useful links on updating a Windows 7 SP1 VM.
Note: if you already have Qubes Windows Tools installed the video adapter in Windows will be "Qubes video driver" and you won't be able to see the Windows Update process when the VM is being powered off because Qubes services would have been stopped by then. Depending on the size of the Windows update packs it may take a bit of time until the VM shutdowns by itself, leaving one wondering if the VM has crashed or still finalizing the updates (in dom0 a changing CPU usage - eg. shown with `xentop` - usually indicates that the VM hasn't crashed).
To avoid guessing the VM's state enable debugging (`qvm-prefs -s win7new debug true`) and in Windows' device manager (My computer -> Manage / Device manager / Display adapters) temporarily re-enable the standard VGA adapter and disable "Qubes video driver". You can disable debugging and revert to Qubes' display once the VM is updated.
Please see the [Customizing Windows 7 templates](/doc/windows-template-customization/) page (despite the focus on preparing the VM for use as a template, most of the instructions are independent from how the VM will be used - ie. TemplateVM or StandaloneVM).