Change VBAT capacitor to DNI.

HackRF One has 100nF capacitor on VBAT. Having 10uF capacitor on PortaPack VBAT may slowly drain the coin cell when in storage, and add a bit of leakage current when installed.
This commit is contained in:
Jared Boone 2015-08-21 11:18:04 -07:00
parent 8dfd68a6b3
commit 1ca4f45d9e

View File

@ -1126,7 +1126,7 @@ L C C41
U 1 1 53A8D62C U 1 1 53A8D62C
P 6500 7200 P 6500 7200
F 0 "C41" H 6550 7300 50 0000 L CNN F 0 "C41" H 6550 7300 50 0000 L CNN
F 1 "10U" H 6550 7100 50 0000 L CNN F 1 "DNI" H 6550 7100 50 0000 L CNN
F 2 "ipc_capc:IPC_CAPC2012X140N" H 6500 7200 60 0001 C CNN F 2 "ipc_capc:IPC_CAPC2012X140N" H 6500 7200 60 0001 C CNN
F 3 "" H 6500 7200 60 0000 C CNN F 3 "" H 6500 7200 60 0000 C CNN
F 4 "Murata" H 6500 7200 60 0001 C CNN "Mfr" F 4 "Murata" H 6500 7200 60 0001 C CNN "Mfr"